- Color & Coating
- Environmental Testing Systems
- Temperature Humidity Chamber
- Ozone , Dust , Rain & Noxious Gas Chamber
- Accelerated Weathering Test Chamber
- Salt Spray Test Chamber
- Drying Oven
- Digital Thermometer
- Digital Temperature & Humidity Meter
- Infrared Thermometer
- Moisture Meter
- Anemometer
- Light Meter
- Sound Level Meter
- Particle Counter
- Vibration Machine
- Gas Detector
- Heater
- Others
- View All
- Material Testing
- Universal Testing Machine
- Charpy Pendulum Impact Tester
- BenchTop Hardness Tester
- Ultrasonic Thickness Gauge
- Portable Hardness Tester
- Shore Rubber & Plastic Hardness Tester
- Surface Roughness Tester
- Ultrasonic Flaw Detector
- Melt Flow Rate Meter (MFI)
- Sample Preparation Machine
- Asphalt & Bitument Testing
- Heat Stress Metter
- Plastic Testing Equipment
- Precise Measurement Solution Provider
- Rheometer
- View All
- Metrology Measuring System
- Portable Measuring & Testing Instruments
- Vibration Meter
- Push Pull Gauge
- Data Logger / Data Logging Instrument
- Digital Tachometer
- Digital Handheld Stroboscope
- Laser Range & Angle Finder
- Laser Distance Meter
- Gauss Meter
- Inspection Mirror
- Welding Gauge
- Adhesion Tester
- Cable Length Measuring Device
- Refractometer
- Rotating Analysis
- TDS
- View All
- Weighing & Metal Detection System
- Electronic & Electrical Testing Equipments
- Lab & Scientific Equipments
- Equipments for Food & Beverage Packaging
- Hot Wire Bottle Cutter
- Vacuum Leak Tester
- Pressure or Vacuum Gauge
- Secure Seal Analyzer
- CO2 Easy / CO2 Easy-DCO2 Measuring Device
- Burn Test
- Can And End Testing Equipments
- CO2 Measure
- Crown Cap Measure & Test
- Cutting Packaging
- Dimensional Measure
- Filtering
- Force Measure/Compresion/Dynamometers
- Stress Aplication
- Torque Measure
- Others
- View All
- Electric Vehicle Equipment
- Ion Fan
- Microscope
- Service Maintenance & Calibration
- Others
Redmark Industry Sdn Bhd
141-2, Jalan Radin Bagus, Bandar Baru Sri Petaling, 57000 Kuala Lumpur, Malaysia.
+603-9054 6939
+6012-499 2103
+6012-499 2103
Redmark Industry (Penang)
Sdn Bhd
7206, Mez Floor, Kompleks Perniagaan Pangsapuri Seri Cemerlang, Jalan Kampung Paya, Kampung Paya, 12200 Butterworth, Penang, Malaysia.
+6013-399 2103
sales@redmarkindustry.comchuin@redmarkindustry.com
Voltage,mA Calibrator
Previous | 1 / 3 | Next |
Features
* Display: 88888 counts
* Measure loop currents signals
* Measure Process signals from PLC
* Simulates 24mA loop current to output
* Source voltage to 100mV or 10V
* Low Battery Display
* Maximum voltage applied between any jack and earth ground or any tow jack: 30V
* Storage temperature: -40¡æ to 60¡æ
* Operating temperature: -10¡æ to 55¡æ
* Operating altitude: 3000 meters maximum
* Temperature coefficient: +/-0.005% of range per ¡æ for the temperature range -10¡æ to 18¡æ and 28¡æ to 55¡æ
* Relative humidity: 95% up to 30¡æ, 75% up to 40¡æ, 45%up to 50¡æ, 35% up to 55¡æ
* Shock: Random 2g, 5Hz to 500Hz
* Safety: 1 meter drop test
* Power requirement: 9VDC, 006P or 1604A
* Size: 190mm(L) x 89mm(W) x 42mm(H)
* Weight: 350g (include battery)
* Auto Power off: 6 min
* Cancel the function of Auto Power Off: Hold Input / Output key, then press Power button. The full screen appears and the
Auto Power Off is canceled. On the contrary, the Auto Power Off could be recovered after reboot the calibrator.
* Safety rating: CE(EMC) RoHS
Specification
Specification Range Resolution Accuracy
DC V mV Input 0~100mV 0.01mV ¡¡
0~10V 0.001V ¡¡
DC V mV Output 0~100mV 0.01mV ¡¡
0~10V 0.001V ¡¡
Loop Power Output 24V DC N/A ¡¡
DC mA Input 0~24 mA 0.001mA ¡¡
DC mA Output 0~24 mA 0.001mA ¡¡
DC V Input and Output 100mV 0.01mV +/-(0.02%+2)
10V 0.001V +/-(0.02%+2)
DC mA Input and Output 24mA 0.001mA +/-(0.015%+4)
Loop Power 24V ¡¡ +/-10%
* Display: 88888 counts
* Measure loop currents signals
* Measure Process signals from PLC
* Simulates 24mA loop current to output
* Source voltage to 100mV or 10V
* Low Battery Display
* Maximum voltage applied between any jack and earth ground or any tow jack: 30V
* Storage temperature: -40¡æ to 60¡æ
* Operating temperature: -10¡æ to 55¡æ
* Operating altitude: 3000 meters maximum
* Temperature coefficient: +/-0.005% of range per ¡æ for the temperature range -10¡æ to 18¡æ and 28¡æ to 55¡æ
* Relative humidity: 95% up to 30¡æ, 75% up to 40¡æ, 45%up to 50¡æ, 35% up to 55¡æ
* Shock: Random 2g, 5Hz to 500Hz
* Safety: 1 meter drop test
* Power requirement: 9VDC, 006P or 1604A
* Size: 190mm(L) x 89mm(W) x 42mm(H)
* Weight: 350g (include battery)
* Auto Power off: 6 min
* Cancel the function of Auto Power Off: Hold Input / Output key, then press Power button. The full screen appears and the
Auto Power Off is canceled. On the contrary, the Auto Power Off could be recovered after reboot the calibrator.
* Safety rating: CE(EMC) RoHS
Specification
Specification Range Resolution Accuracy
DC V mV Input 0~100mV 0.01mV ¡¡
0~10V 0.001V ¡¡
DC V mV Output 0~100mV 0.01mV ¡¡
0~10V 0.001V ¡¡
Loop Power Output 24V DC N/A ¡¡
DC mA Input 0~24 mA 0.001mA ¡¡
DC mA Output 0~24 mA 0.001mA ¡¡
DC V Input and Output 100mV 0.01mV +/-(0.02%+2)
10V 0.001V +/-(0.02%+2)
DC mA Input and Output 24mA 0.001mA +/-(0.015%+4)
Loop Power 24V ¡¡ +/-10%