- Color & Coating
- Environmental Testing Systems
- Temperature Humidity Chamber
- Ozone , Dust , Rain & Noxious Gas Chamber
- Accelerated Weathering Test Chamber
- Salt Spray Test Chamber
- Drying Oven
- Digital Thermometer
- Digital Temperature & Humidity Meter
- Infrared Thermometer
- Moisture Meter
- Anemometer
- Light Meter
- Sound Level Meter
- Particle Counter
- Vibration Machine
- Gas Detector
- Heater
- Others
- View All
- Material Testing
- Universal Testing Machine
- Charpy Pendulum Impact Tester
- BenchTop Hardness Tester
- Ultrasonic Thickness Gauge
- Portable Hardness Tester
- Shore Rubber & Plastic Hardness Tester
- Surface Roughness Tester
- Ultrasonic Flaw Detector
- Melt Flow Rate Meter (MFI)
- Sample Preparation Machine
- Asphalt & Bitument Testing
- Heat Stress Metter
- Plastic Testing Equipment
- Precise Measurement Solution Provider
- Rheometer
- View All
- Metrology Measuring System
- Portable Measuring & Testing Instruments
- Vibration Meter
- Push Pull Gauge
- Data Logger / Data Logging Instrument
- Digital Tachometer
- Digital Handheld Stroboscope
- Laser Range & Angle Finder
- Laser Distance Meter
- Gauss Meter
- Inspection Mirror
- Welding Gauge
- Adhesion Tester
- Cable Length Measuring Device
- Refractometer
- Rotating Analysis
- TDS
- View All
- Weighing & Metal Detection System
- Electronic & Electrical Testing Equipments
- Lab & Scientific Equipments
- Equipments for Food & Beverage Packaging
- Hot Wire Bottle Cutter
- Vacuum Leak Tester
- Pressure or Vacuum Gauge
- Secure Seal Analyzer
- CO2 Easy / CO2 Easy-DCO2 Measuring Device
- Burn Test
- Can And End Testing Equipments
- CO2 Measure
- Crown Cap Measure & Test
- Cutting Packaging
- Dimensional Measure
- Filtering
- Force Measure/Compresion/Dynamometers
- Stress Aplication
- Torque Measure
- Others
- View All
- Electric Vehicle Equipment
- Ion Fan
- Microscope
- Service Maintenance & Calibration
- Others
Redmark Industry Sdn Bhd
141-2, Jalan Radin Bagus, Bandar Baru Sri Petaling, 57000 Kuala Lumpur, Malaysia.
+6012-499 2103
Redmark Industry (Penang)
Sdn Bhd
7206, Mez Floor, Kompleks Perniagaan Pangsapuri Seri Cemerlang, Jalan Kampung Paya, Kampung Paya, 12200 Butterworth, Penang, Malaysia.
chuin@redmarkindustry.com
Particle Counter PCE-PCO 2
Previous | 38 / 38 | Next |
Portable handheld device for monitoring particulate matter (PM) concentrations in the air / 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm and 10 µm particle sizes / Measures air temperature, dew point and relative humidity
This is a portable handheld particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures formaldehyde air temperature, dew point and relative humidity.
The particle counter is ideal for monitoring clean rooms, exposure to exhaust, smoke and other harmful air pollutants, and levels of airborne combustible dust such as agricultural dust, carbonaceous dust, chemical dust, metal dust, plastic dust and wood dust.
A variety of materials are explosive in dust form. Some examples include: food (e.g., candy, sugar, spice, starch, flour and feed), grain, tobacco, plastics, wood, paper, pulp, rubber, pesticides, pharmaceuticals, dyes, coal and metals (e.g., aluminum, chromium, iron, magnesium and zinc). These materials are used in agriculture, chemical manufacturing, pharmaceutical production, furniture, textiles, fossil fuel power generation, recycling operations, metal working and processing (including additive manufacturing and 3D printing) and many other industries and processes.
In addition to being a combustion hazard, certain kinds of dust can be a health hazard. Exposure (such as skin contact, eye contact and inhalation) can be linked to sneezing, a stuffy or runny nose, itchy or red eyes, headaches, fatigue, fever, cough, shortness of breath, dermatitis, asthma, bronchitis, pneumonia (e.g., Legionnaires’ disease and hypersensitivity pneumonitis) and cancer.
When inhaled, PM 2.5 and PM 10 particles can settle deep into the lungs and result in damaging health effects. Since the PCE-PCO 2 particle counter monitors PM 2.5 and PM 10 particles, the device has many practical health and safety applications. Heating, ventilation and air conditioning (HVAC) technicians use PM 2.5 and PM 10 particle counters for HVAC system performance and filtration audits. In addition, industrial hygienists and workplace safety professionals rely on PM 2.5 and PM 10 particle counters when evaluating occupational health and safety risks related to hazardous and combustible dust.
- Captures 6 particle sizes
- Measures air temperature, dew point and relative humidity
- 2.8'' TFT full-color LCD screen
- Built-in camera for image and video recording
- Cumulative, differential and concentration particle counting modes
- Stores up to 5,000 data sets to memory
- Power-saving automatic shutdown feature
- PM channels: PM 2.5, PM 10, including mass concentration mode (µg/m³)
- Free software download on PCE Software web page
Specifications
Particle specifications | |
Particulate matter channels | PM 2.5 / PM 10 |
Particle concentrations | 0 ... 2000 μg / m³ |
Resolution | 1 μg / m³ |
Particle counter specifications | |
Particle sizes (in micrometers) | 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 μm |
Flow rate | 2.83 l / min |
Coincidence error | < 5 % at 2,000,000 particles per cubic foot |
Counting efficiency |
50 % at 0.3 μm; 100 % with particle size > 0.45 μm |
Memory capacity | Stores up to 5,000 data sets |
Counting modes | Cumulative, differential, concentration |