- Color & Coating
- Environmental Testing Systems
- Temperature Humidity Chamber
- Ozone , Dust , Rain & Noxious Gas Chamber
- Accelerated Weathering Test Chamber
- Salt Spray Test Chamber
- Drying Oven
- Digital Thermometer
- Digital Temperature & Humidity Meter
- Infrared Thermometer
- Moisture Meter
- Anemometer
- Light Meter
- Sound Level Meter
- Particle Counter
- Vibration Machine
- Gas Detector
- Heater
- Others
- View All
- Material Testing
- Universal Testing Machine
- Charpy Pendulum Impact Tester
- BenchTop Hardness Tester
- Ultrasonic Thickness Gauge
- Portable Hardness Tester
- Shore Rubber & Plastic Hardness Tester
- Surface Roughness Tester
- Ultrasonic Flaw Detector
- Melt Flow Rate Meter (MFI)
- Sample Preparation Machine
- Asphalt & Bitument Testing
- Heat Stress Metter
- Plastic Testing Equipment
- Precise Measurement Solution Provider
- Rheometer
- View All
- Metrology Measuring System
- Portable Measuring & Testing Instruments
- Vibration Meter
- Push Pull Gauge
- Data Logger / Data Logging Instrument
- Digital Tachometer
- Digital Handheld Stroboscope
- Laser Range & Angle Finder
- Laser Distance Meter
- Gauss Meter
- Inspection Mirror
- Welding Gauge
- Adhesion Tester
- Cable Length Measuring Device
- Refractometer
- Rotating Analysis
- TDS
- View All
- Weighing & Metal Detection System
- Electronic & Electrical Testing Equipments
- Lab & Scientific Equipments
- Equipments for Food & Beverage Packaging
- Hot Wire Bottle Cutter
- Vacuum Leak Tester
- Pressure or Vacuum Gauge
- Secure Seal Analyzer
- CO2 Easy / CO2 Easy-DCO2 Measuring Device
- Burn Test
- Can And End Testing Equipments
- CO2 Measure
- Crown Cap Measure & Test
- Cutting Packaging
- Dimensional Measure
- Filtering
- Force Measure/Compresion/Dynamometers
- Stress Aplication
- Torque Measure
- Others
- View All
- Electric Vehicle Equipment
- Ion Fan
- Microscope
- Service Maintenance & Calibration
- Others
Redmark Industry Sdn Bhd
141-2, Jalan Radin Bagus, Bandar Baru Sri Petaling, 57000 Kuala Lumpur, Malaysia.
+603-9054 6939
+6012-499 2103
+6012-499 2103
Redmark Industry (Penang)
Sdn Bhd
7206, Mez Floor, Kompleks Perniagaan Pangsapuri Seri Cemerlang, Jalan Kampung Paya, Kampung Paya, 12200 Butterworth, Penang, Malaysia.
+6013-399 2103
sales@redmarkindustry.comchuin@redmarkindustry.com
Electric Vehicle EVSE Tester PCE-EVSE 300
Previous | 4 / 5 | Next |
EVSE adapter for charging plugs type 1 and 2 / PP and CP simulation
Shock-proof socket connection / Direct acceptance of all connections via laboratory plugs
Electromobility is playing an increasingly important role. An important point here are the charging stations for electric vehicles. Special measuring devices are needed to check the function, protective devices and insulation of permanently installed charging stations, also known as wallboxes. Often, measuring devices are already available to perform the required measurements. An adapter is therefore required so that the measuring device can be connected to the charging station.
The EVSE adapter is specially designed for this application and already comes with a variety of functions. For example, all lines leaving the charging station are output individually via laboratory plugs. Thus, all lines can be tapped via the EVSE adapter. This allows the charging station to be checked for insulation with the help of the EVSE adapter. The EVSE adapter has a shock-proof plug connection. The RCD tester can be used to check the residual current device.
A charging cable not only contains the supply lines for charging an electric vehicle, but also two interfaces. The electric vehicle communicates with the charging station via the CP line (Control Pilot) and communicates the current status of the electric vehicle. The PP line (Proximity Plug) is used for communication between the connected charging cable and the charging station. The charging cable can thus tell the charging station how many amps it may be loaded with. To test both functions, the EVSE adapter is equipped with corresponding simulators.
The EVSE adapter is specially designed for this application and already comes with a variety of functions. For example, all lines leaving the charging station are output individually via laboratory plugs. Thus, all lines can be tapped via the EVSE adapter. This allows the charging station to be checked for insulation with the help of the EVSE adapter. The EVSE adapter has a shock-proof plug connection. The RCD tester can be used to check the residual current device.
A charging cable not only contains the supply lines for charging an electric vehicle, but also two interfaces. The electric vehicle communicates with the charging station via the CP line (Control Pilot) and communicates the current status of the electric vehicle. The PP line (Proximity Plug) is used for communication between the connected charging cable and the charging station. The charging cable can thus tell the charging station how many amps it may be loaded with. To test both functions, the EVSE adapter is equipped with corresponding simulators.
- CP and PP simulation
- Transport bag included in delivery
- Direct connection for wallboxes
- Adapter with type 1 and type 2 charging plugs
- PE conductor test
- Integrated shock-proof socket
unctions | |
PE test (protective conductor) | available, error |
PP simulation (charging cable coding) | open, 13 A, 20 A, 32 A, 63 A |
CP simulation (communication line) | A, B, C, D, error |
Outputs (only for test purposes) | |
Measuring connections | L1, L2, L3, N, PE |
max. 250 / 430 V AC, 10 A | |
laboratory plug | |
Schuko connection | max. 250 V AC, 10 A |
Fuse from the Schuko connection | fuse F 10 A / 250 V, 5 x 20 mm / 0.19 x 0.78'' |
CP signal output | ± 12 V PWM |
Further specifications | |
Input voltage | 1 phase: 250 V AC / 3 phase 430 V AC, |
50 / 60 Hz, max. 10 A | |
Charging cable connector Type 1 | AC charging mode 3, compatible with IEC62196-1 |
Type 1 or SAE J1772 with vehicle connection | |
(Type 1, 5 pin, 1-phase) | |
Charging cable connector Type 2 | AC charging mode 3, compatible with IEC62196-2 |
Type 1 or SAE J1772 with vehicle connection | |
(Type 2, 7 pin, 3-phase) | |
Measurement category | CAT II 300 V |
Protection class | IP54 |
Pollution degree | 2 |
Operating conditions | 0 ... 40 °C / 32 ... 104 °F, 10 ... 85% RH, non-condensing |
Storage conditions | -10 ... 50 °C / 14 ... 122 °F, 10 ... 60% RH, non-condensing |
Maximum working height | max. 2000 m / 6561 ft |
Dimensions (handheld only) | 277 x 109 x 63 mm / 10.9 x 4.3 x 2.4'' |
Weight |
ca. 1 kg / 2.2 lb |
Delivery Scope
1 x Electric Vehicle EVSE Tester PCE-EVSE 300
1 x Charging cable plug type 1
1 x Charging cable plug type 2
1 x Transport bag
1 x Instruction manual