- Color & Coating
- Environmental Testing Systems
- Temperature Humidity Chamber
- Ozone , Dust , Rain & Noxious Gas Chamber
- Accelerated Weathering Test Chamber
- Salt Spray Test Chamber
- Drying Oven
- Digital Thermometer
- Digital Temperature & Humidity Meter
- Infrared Thermometer
- Moisture Meter
- Anemometer
- Light Meter
- Sound Level Meter
- Particle Counter
- Vibration Machine
- Gas Detector
- Heater
- Others
- View All
- Material Testing
- Universal Testing Machine
- Charpy Pendulum Impact Tester
- BenchTop Hardness Tester
- Ultrasonic Thickness Gauge
- Portable Hardness Tester
- Shore Rubber & Plastic Hardness Tester
- Surface Roughness Tester
- Ultrasonic Flaw Detector
- Melt Flow Rate Meter (MFI)
- Sample Preparation Machine
- Asphalt & Bitument Testing
- Heat Stress Metter
- Plastic Testing Equipment
- Precise Measurement Solution Provider
- Rheometer
- View All
- Metrology Measuring System
- Portable Measuring & Testing Instruments
- Vibration Meter
- Push Pull Gauge
- Data Logger / Data Logging Instrument
- Digital Tachometer
- Digital Handheld Stroboscope
- Laser Range & Angle Finder
- Laser Distance Meter
- Gauss Meter
- Inspection Mirror
- Welding Gauge
- Adhesion Tester
- Cable Length Measuring Device
- Refractometer
- Rotating Analysis
- TDS
- View All
- Weighing & Metal Detection System
- Electronic & Electrical Testing Equipments
- Lab & Scientific Equipments
- Equipments for Food & Beverage Packaging
- Hot Wire Bottle Cutter
- Vacuum Leak Tester
- Pressure or Vacuum Gauge
- Secure Seal Analyzer
- CO2 Easy / CO2 Easy-DCO2 Measuring Device
- Burn Test
- Can And End Testing Equipments
- CO2 Measure
- Crown Cap Measure & Test
- Cutting Packaging
- Dimensional Measure
- Filtering
- Force Measure/Compresion/Dynamometers
- Stress Aplication
- Torque Measure
- Others
- View All
- Electric Vehicle Equipment
- Ion Fan
- Microscope
- Service Maintenance & Calibration
- Others
Redmark Industry Sdn Bhd
141-2, Jalan Radin Bagus, Bandar Baru Sri Petaling, 57000 Kuala Lumpur, Malaysia.
+6012-499 2103
Redmark Industry (Penang)
Sdn Bhd
7206, Mez Floor, Kompleks Perniagaan Pangsapuri Seri Cemerlang, Jalan Kampung Paya, Kampung Paya, 12200 Butterworth, Penang, Malaysia.
chuin@redmarkindustry.com
Power Analyzer F50
Previous | 2 / 5 | Next |
The power analyzer measures current and voltage values by means of the connected current transformers and test leads. From this, the active, apparent and reactive power is determined and transmitted to the measuring platform every second via WLAN. There, the data is stored historically, graphically processed and can be evaluated or exported. Measurement with the power analyzer is carried out via Rogowski coils or folding current transformers.
Alternatively (if there is no internet connection), the data can be recorded in the built-in, 8 MB flash memory in the form of a CSV file for further processing later. An SD card adapter is also available as an accessory, which means that the recording time is more than a year, even when recorded to the second. It is also possible to send the CSV files periodically via e-mail, upload them to a server via FTP or transfer them to the measurement platform after the measurement has been completed. Interaction with the power analyzer is mainly via WLAN and web browser or via app (BLE).
The power supply and measurement is carried out via magnetic measuring tips and connection terminals or test probes. The power analyzer can be connected to any main and sub-distribution as well as to devices and systems - the power supply does not have to be interrupted. Managing the power supply is a top priority. Without measuring consumption and recording instrumental values such as current, voltage, frequency and power, it is hardly possible to improve efficiency. The energy meter allows you to monitor the total energy consumption and helps to reduce energy costs.
Characteristics
Specification
AC voltage AC | |
Measuring range | 40 ... 400 V |
Resolution | 0.01 V |
Accuracy | ±1% v.Mw. |
Wechselstrom AC | |
Measuring range | 2 ... 1250 A |
Resolution | 0.01 A |
Accuracy | ±1% v.Mw. |
Active power | |
Measuring range | 80 W ... 500 kW |
Resolution | 0.01 W |
Accuracy | ±1% v.Mw. |
Reactive power | |
Measuring range | 80 VAR ... 500 kVAR |
Resolution | 0.01 VAR |
Accuracy | ±1% v.Mw. |
Apparent power | |
Measuring range | 80 VA ... 500 kVA |
Resolution | 0.01 VA |
Accuracy | ±1% v.Mw. |
Power factor | |
Measuring range | 0 ... 1 |
Resolution | 0,01 |
Accuracy | ±1% v.Mw. |
General technical data | |
Sampling Rate | 26000 Hz |
Recording medium | Internal memory |
Storage capacity | 8 MB |
Storage capacity (additional information) | separate phases: 22000 records, combined phases: 38000 records |
Storage interval of | 1 s |
Storage interval to | 60 min. |
Current Consumption Power Analyzer | 100 mA DC |
Maximum cable diameter | 49 mm |
Safety standard | CAT III 300V |
Fuse(s) | 250mA, FA, IR>=30kA |
Language | German, English (GB), English (US), Spanish, French |
Protection class (device) | IP40 |
Power supply |
100 ... 240 V 50/60 Hz (+/- 10%) (between neutral and phase A) |
Weight | 202 g |
Service conditions | -5 ... 40 °C , 0 ... 80 % RH |
Storage | -5 ... 40 °C , 0 ... 80 % RH |
Dimensions ( L x W x H ) | 123 x 96 x 36 mm |