2

Share:


IPX9k High Pressure Tester

Protection against water from high pressure steam jet cleaners. High pressure and temperature water is jetted at an enclosure to test for ingress protection. IPX9K testing is the highest level of water ingress testing per the IP Code system.


Technical Parameters

Model IPX9k High Pressure Tester
Internal dimensions (mm)  1000*1200*1000 D*W*H
Overall dimensions (mm) 1250* 1700* 2050 D*W*H
Water Spray Temperature ambient ~ 88℃ (Adjustable)
Water Spray Angle 0°,30°,60°,90°
Spray Nozzle Four, 30 seconds each position
Spray Range 30° ± 5°(Single hole);   Space 100-150mm
Distance from water spraying to specimens        10~15cm
Water Pressure 8000-10000 Kpa (adjustabl)
Water Flow Rate 14L-16L/min
Testing Platform Speed 5 ±1 r.p.m
Test Platform height 200-450mm, adjustable  
Test Platform diameters 600mm
Load ≤100kg
Controller Programmable color display touch screen controller
PC Link with software, R-232 interface
Pressure meter Alarm function Power protection, timing (to be automatic stop), water protection, motor overheating protection, water temperature overheating automatic drainage, water function
Operating environment Grading, no corrosive gas, avoid direct sunlight, etc Temperature: +5~+35 C; Humidity: 45~85%RH   
Power Supply 380V 50HZ, Three-phase five-wire


 Inquiry - IPX9k High Pressure Tester